Aerosol Diluter ATI – TDA D10 / TDA D100

Aerosol Diluter ATI – TDA D10 / TDA D100

. Compatible with any 1 cfm particle counter.
. Minimizes pressure drops and aerosol loss.
. Available in 10:1 and 100:1 dilution ratio configurations.
. Can be plumbed in series for alternate dilution configurations.
. Ideal for isolators, mask fittings and installation with low airflows.
. Works with any type of aerosol challenge, including PSL, PAO, DOP, and NaCl.

Download product sheet

Need information

Share Product

Click here

Product Specifications

Dilutes aerosol to measurable levels for particle counters.
Installed between the aerosol source and a particle counter, diluters minimize pressure drop and aerosol loss while preventing saturation of the particle counter.

Dilution Ratio: D10 – 10:1 | D100 – 100:1

Particle Size of Interest: 0.1, 0.3 or 0.5 micron

Air Flow Rate: 1 cfm (28.3 lpm)

Pressure Drop: Nominally ≤ 1 in. Water Column (25 mm WC)

Electrical: Not required

Run Time Meter: Included

Material: Stainless Steel

Operational Inlet / Outlet: 0.325 in. Tubing ID | 0.25 in. Tubing ID Optional

Size: 15.5 cm x 8.3 cm x 55.9 cm (6.5 in. x 3.3 in. x 22.0 in.)
Weight: 3.0 kg (7.0 lb)
Maintenance: Replace internal bypass filters as necessary. Ultrasonic cleaning of annular orifice. Clean or replace tubing as required.

* Note: Flow rate and particle size of interest can be configured to customer requirements

Application:
Pharmaceutical manufacturers.
Medical facilities and cleanrooms.

Associated services

. Training in the use of the device, remotely or on site, and in the use of the data.

. Performance of metrological verification services in our laboratory located in Betton (35).

You may also like…

  • Portable Airborne Particle Counter CLIMET CI-570

    . New generation NextGen series.
    . The lightest and smallest particle counter for ISO 7 and ISO 8 classes.
    . Flow rate: 50 LPM.
    . 6 channels: from 0.3 to 10 µm.
    . Integrated PDF reports/Audit trail and user traceability.
    . Complies with ISO 21501-4.

    Download the product sheet
  • Thermal Aerosol Generator ATI Model TDA 5D

    . Hepa Filter Testing ISO 14644-3.
    . Fast operation with a warm-up time of only 60 seconds.
    . Widest range of System Flow Rates 850 – 120.000 m3/hr.
    . Rugged Portability.
    . Safe and reliable Operation.
    . Flex-Fuel Capacity.
    . Lightweight and rugged, ideal for remote locations.

  • Photomètre ATI 2i pour réalisation de tests d'intégrité de filtre HEPA avec une iProbe

    Photometer ATI Model TDA 2i

    . Hepa Filter Testing ISO 14644-3.
    . Lightweight, portable and rugged digital photometer
    Large.
    . 4.3″ LCD screen to display critical information.
    . iProbe (optional) with 12 ft cable for hard to reach areas minimizes downtime.
    . User settable aerosol noise suppression for more stable aerosol measurements.
    . Printer (optional) available for reporting.